The 2021 Shanghai Munich electronics exhibition will be held in Shanghai New International Expo Center from April 14 to 16 this week. Pico technology will display its series of new products and products and solutions with unique characteristics. The specific display contents include: Pocket oscillograph, data recorder scheme, adjustable high-resolution oscillograph, eight channel deep storage oscillograph, four channel real differential oscillograph, high-speed eye diagram &tdr tester, user-defined programming application scheme, vector network and RF source scheme. Welcome to our booth n4.4230 for more details and operation experience.

Pico technology latest and typical product information overview:

PicoScope 6000e series: a new generation of intelligent oscilloscope for efficient debugging

summary:

PicoScope 6000e series fixed resolution and adjustable resolution oscilloscopes can provide 8 to 12 bit vertical resolution, with a bandwidth of 500MHz and a sampling rate of 5gs/s.

Models with four or eight analog channels have the time and amplitude resolution required to reveal signal integrity problems, such as timing errors, faults, losses, crosstalk, and metastable problems.

Video link:

https://v.youku.com/v_show/id_XNDU2OTc0NzEzMg==.html ? spm=a2h0c. 8166622.PhoneSokuUgc_ 19.dTItle

Specifications:

8-bit to 12 bit flexres ® ADC; 4 or 8 analog channels can be selected; Add 8 or 16 digital MSO channels; Up to 500 MHz bandwidth; 200ms waveform can be captured at 5 gs/s; Up to 4gs capture memory; 50MHz, 200ms/s, 14 bit AWG; USB3.0 interface; 300000 waveform update rate per second; Standard PicoScope 6 software and picosdk; 21 serial protocol decoding software are configured as standard; Standard template tolerance test and user definable alarm function; High resolution time stamp information of waveform can be provided; Each acquisition can achieve more than 10 million depth measurements; Standard advanced triggers such as edge, window, pulse width, window pulse width, level leakage, window leakage, interval, under amplitude and logic.

Page link:https://www.picotech.com/oscilloscope/6000/picoscope-6000-overview

Manual document download link:https://www.picotech.com/download/manuals/picoscope-6000e-series-data-sheet.pdf

Picovna108: make vector network analysis everywhere

summary:

The high performance, portability and low cost of picovna vector network analyzer are suitable for field service, installation and testing, OEM embedded and classroom applications. With their remote automation capabilities, they are also attractive in the fields of test automation, manufacturers, electronic components, assembly and systems, materials, geology, life and Food Sciences, antenna matching and tuning.

Video link:

https://v.youku.com/v_show/id_XMjg4MjgyMjM2MA==.html ? spm=a2h0c. 8166622.PhoneSokuUgc_ 1.dTItle

Specifications:

300 kHz to 6 or 8.5 GHz frequency range; High speed rate of up to 5500 dual port s parameters per second; More than 10000 s11+s21 measurements per second; Quad RX four receiver structure can obtain the best accuracy; Up to 124 DB dynamic range at 10 Hz bandwidth; There is only about 0.005db RMS baseline noise under the maximum bandwidth of 140khz; Half rack, small floor area and light weight; Control via USB from Microsoft Windows interface on PC; The standard configuration has the functions of reference plane offset and de embedding; Time domain and port impedance conversion; Print and save forms and graphics, including touchstone files; Configured with trigger save automation function (picovna 108); Dual frequency mixer measurement with VSWR correction (picovna 108); P1db, am to PM and independent signal generator functions; Calibration process wizard with 8 and 12 items and absolute power; 6 calibration modes, including unknown pass through and connected DUT isolation; Calibration and standard test pieces are provided to ensure that the measurement results of the equipment are reliable.

Page link:https://www.picotech.com/vector-network-analyzer/picovna/picovna-series

Manual document download link:https://www.picotech.com/download/datasheets/picovna-vector-network-analyzer-data-sheet.pdf

PicoScope 9400 series: 5&16ghz sampler extended real-time oscilloscope

summary:

PicoScope 9400 series is a new type of sampler expansion (sxrto) real-time oscilloscope, which combines the advantages of real-time sampling, equivalent time sampling and high analog bandwidth.

Video link:

https://v.youku.com/v_show/id_XNDA4NjU4MTkxMg==.html ? spm=a2h0c. 8166622.PhoneSokuUgc_ 6.dTItle

Specifications:

Sxrto (sampler extended real-time oscilloscope); 9404-16:16 GHz bandwidth, 22 PS rise time and 2.5 ts/s (0.4 PS resolution) equivalent time sampling; 9404-05:5 GHz bandwidth, 70 PS rise time and 1 ts/s (1 ps resolution) equivalent time sampling; Pulse, up to 8gb/s eye diagram and template test; Four 12 bit 500ms/s ADC; Intuitive and configurable touch compatible Windows user interface; Comprehensive built-in measurement, scaling, data templates and histograms; ± 800 MV full scale input range to 50 Ω; The digital gain can be adjusted from 10 mv/div to 0.25v/div; Record length up to 250ks, shared between channels; Optional clock and data recovery (8 gb/s for 9404-16 and 5 gb/s for 9404-05).

Page link:https://www.picotech.com/oscilloscope/9400/sxrto-sampler-extended-real-TIme-ghz-oscilloscope

Manual document download link:https://www.picotech.com/download/datasheets/picoscope-9400-series-sxrto-data-sheet.pdf

PicoScope 9300 series: 25ghz sampling oscilloscope with models for tdr/tdt and optical signal test

summary:

The bandwidth of PicoScope 9300 sampling oscilloscope is up to 25ghz, which can meet digital and communication applications of 10gb/s and higher, microwave applications of 25ghz and timing measurement applications with resolution as low as 64fs. The optional 11.3 gb/s clock recovery, photoelectric converter or differential time domain reflectometer source (60 ps/7 V) makes it a powerful, small footprint and cost-effective measurement package.

Video link:

https://tv.sohu.com/v/dXMvNTAzMzMxMDEvMjgwODU3Mzcuc2h0bWw=.html ? spm=a2h0c. 8166622.PhoneSokuUgc_ 26.dtitle

Specifications:

Main specifications: 15ts/s (64 FS) sequential sampling; Up to 15 GHz pre trigger, 2.5 GHz direct trigger and 11.3gb/s clock recovery; Industry leading 16 bit 1 ms/s ADC and 60 dB dynamic range; Eye diagram and template test to 16gb/s, including up to 2e23 – 1-yard lock; Intuitive touch compatible with Windows user interface; Comprehensive built-in measurement, histogram and editable data template library; Integrated, differential and offset adjustable tdr/tdt step generator;

Typical applications: communication and radar testing, service and manufacturing; Optical fiber, transceiver and laser test; RF, microwave and Gigabit digital system measurement; Radar band I, G, P, l, s, C, x, Ku; Precise timing and phase analysis; Digital system design and characteristic description; Eye diagram, template and tolerance test up to 10gb/s; Ethernet, HDMI 1, HDMI 2, PCI, SATA, USB 2.0, USB 3.0; Tdr/tdt analysis of cable, connector, backplane, PCB and network; Semiconductor characteristic description, etc.

Page link:https://www.picotech.com/oscilloscope/9300/picoscope-9300-sampling-oscilloscopes

Manual document download link:https://www.picotech.com/download/datasheets/picoscope-9300-series-sampling-oscilloscopes-data-sheet.pdf

PicoScope 4000A series: crystal clear waveform analysis

summary:

PicoScope 4000A series PC oscilloscope is the second generation upgrade and expansion of our high-resolution, deep memory product portfolio.

The PicoScope 4000A series is available in 2, 4, and 8-channel models with 12 bit hardware resolution (software enhancements to increase the resolution to 16 bits), 256ms deep capture memory, 20MHz bandwidth and 80ms/s sampling speed, up to 70dB SFDR, as well as a built-in 14 bit trigger generator and 80 ms/s AWG. The ultra-high speed USB 3.0 interface supplies power to the instrument and provides up to 160 ms/s communication to the host PC.

Video link:https://www.youtube.com/embed/r122FnXAqMg

Specifications:

2. 4 or 8 channels; 20MHz bandwidth; 12 bit resolution; 256 MS capture memory; 80 ms/s sampling rate; 1% dc accuracy; ± 10 MV to ± 50 V input range; 10000 segment waveform buffer; 80ms/s AWG update rate; 14 bit resolution AWG; Low cost and portable; Ultra high speed USB 3.0 interface; Split screen waveform viewing; Up to 70dB SFDR; Advanced digital trigger; Serial bus decoding; Including PicoScope and picosdk ® Software.

Page link:https://www.picotech.com/oscilloscope/4000/picoscope-4000-series

Manual document download link:https://www.picotech.com/download/datasheets/picoscope-4000a-series-oscilloscope-data-sheet.pdf

PicoScope 4444: true differential and high resolution oscilloscope

summary:

PicoScope 4444 is a high-resolution oscilloscope with four true differential input channels and measurement accessories, suitable for low-voltage and high-voltage applications. The latest product solution of PicoScope 4444 solves a long-standing problem, that is, to accurately measure the voltage waveform on the circuit elements without grounding reference, without the risk of short circuit that may damage the tested equipment or measuring instruments.

Video link:

https://v.youku.com/v_show/id_XMjg4MDU2Njc3Ng==.html ? spm=a2h0c. 8166622.PhoneSokuUgc_ 15.dtitle

Specifications:

Main features: 4 fully differential high impedance inputs; 20MHz bandwidth; Flexible 12 bit and 14 bit resolutions; 256ms deep storage; Common mode noise suppression capability; Intelligent probe and fixture interface; Low voltage probe for MV to 50 V; 1000 volt catiii voltage and current probes for mains measurement applications; 10000 waveform cycle buffers; Up to 100000 waveforms per second; Serial bus decoding; Formwork tolerance test; Advanced mathematical functions and filtering; Statistical measurement; Advanced digital trigger; USB3.0 connection and power supply.

Typical application: non reference ground measurement; Safe detection of single-phase and three-phase voltages and currents; Power measurement of mobile and Internet of things devices; Power quality test; Switching power supply design; Hybrid and electric vehicle design; Motor drive and inverter; Biomedical electronics; Differential signals (can, balanced audio) can be measured using one channel.

Page link:https://www.picotech.com/oscilloscope/4444/picoscope-4444-overview

Manual document download link:https://www.picotech.com/download/datasheets/picoscope-4444-data-sheet.pdf

Picosourceas108:8ghz RF signal synthesizer

summary:

Video link:https://www.youtube.com/embed/2s4wl3rh-1g

Specifications:

300 kHz to 8 GHz operating frequency range; – 15 DBM to +15 DBM dynamic range; Fast 55 μ S frequency setting stabilization time to 10 ppm; Fast amplitude setting stabilization time: 25 μ S to 1dB, 200 μ S to 0.1 dB; Scan, jump and list of frequency and level or list of phase and level; − 100 dbc/hz phase noise, typical frequency is 1 GHz and 10kHz offset; FM, Ø m and am modulation, based on internal sine or external input; External reference clock i/o and trigger i/o; Use scan list to simulate QPSK, QAM, ask, FSK and other schemes; Adjustable dwell and trigger scanning or trigger next point mode; Use and convert measurement units to suit specific applications; Programming examples of LabVIEW, C, c\y, Python and MATLAB; Suitable for desktop, field and system integration applications; Control via windowspc and display or tablet based on USB; Touch, mouse, keyboard or remote interface software (including API); Multi unit operation with synchronous modulation, scanning, hopping and listing; Configurable independent operation mode.

Page link:https://www.picotech.com/agile-synthesizer/picosource-as108/picosource-as108-overview

Manual document download link:https://www.picotech.com/download/manuals/picosource-as108-agile-synthesizer-data-sheet.pdf

Picologgertc-08: best selling 8-channel temperature recorder

summary:

The TC-08 thermocouple data logger is designed to achieve a wide range of temperature measurements using any thermocouple measurement with a miniature thermocouple connector. Based on TC-08 thermocouple data recorder, you can realize fast and accurate temperature measurement. In addition to using thermocouples to measure temperature, the terminal board also allows TC-08 to connect other sensors with voltage or current output. Using TC-08 for temperature data acquisition is very simple – just plug TC-08 into the USB port of the computer (no external power supply is required) and connect the thermocouple to measure the temperature.

Video link:https://www.youtube.com/embed/nMKLonAQmgA

Specifications:

8-channel thermocouple data recorder; Measuring range from -270 to +1820 ° C (– 454 to +3308 ° f); High resolution and precision; It can be expanded to 20 sets /160 channels and displayed on one software interface; Support all popular thermocouple types; Fast sampling rate – up to 10 measurements per second (including CJC); USB connection and power supply; Standard configuration of data recording software PicoLog 6 based on windows, MacOS and Linux; Includes picosdk drivers for custom development on windows, MacOS, and Linux.

Page link:https://www.picotech.com/data-logger/tc-08/thermocouple-data-logger

Manual document download link:https://www.picotech.com/download/datasheets/usb-tc-08-thermocouple-data-logger-data-sheet.pdf

Leave a Reply